Part #YTHX1200B8/U
ElitePRO S1200 w/ EIM Kit - Black

Login for Price
- Brand: Honeywell
- WiFi streams video from First Alert® and Ring® doorbells
- Works with residential and commercial systems up to 4H/2C heat pump or 3H/3C conventional
- Control up to 2 IAQ devices¹ with configurable outputs
- Monitor indoor humidity, VOC, and estimated CO2
- Expandable application coverage and simplified installation with use of equipment interface module (EIM)
- Compatible with dual fuel, fan-coil, PTAC, and radiant systems
- Advanced occupancy detection helps save energy
- Redlink™ 3.0 technology connects wirelessly with Room Sensors (temp, humidity, & motion), EIM, and Outdoor Sensors (temp & humidity)
- Prioritize the comfort of the room of choice with remote Room Sensors
- Homeowners can control from anywhere using the First Alert by Resideo app
- Demand response capable
- 2.4 GHz or 5GHz WiFi connection
- Works with Google Home, Amazon Alexa, and Apple Home
- 5-year warranty
- Application Residential or light commercial, 24 Vac systems; Gas, Oil, Electric Warm Air, Hydronic, Fan coil unit, PTAC. IAQ control.
- Dimensions (in.)(Thermostat) 5.25 W X 3.54 H X 0.96 D
- Dimensions (mm)(Thermostat) 90 H x 133 W x 24 D
- Includes Thermostat, Wireless indoor sensor, EIM
- Mounting Horizontal Mount to wall or J-Box
- Frequency 60 Hz
- Stages 4H/2C Heat Pump or 3H/4C conventional
- Operating Humidity Range (% RH) 5% to 90% RH, non-condensing
- Supply Voltage 20 to 30 VAC
- Switch Positions (System)(Touchscreen) Heat, off, cool, auto, em heat
- Switch Positions (Fan) (Touchscreen) on, auto, circ, (fan speeds for some systems)
- Operating Temperature Range (F) 37° to 102° F
- Operating Temperature Range (C) 2.8° to 38.9° C
- Shipping and Storage Temperature Range (F) -20 °F to 120 °F
- Shipping and Storage Temperature Range (C) -29 °C to 49 °C
- Network Communications Redlink 3.0, WiFi (2.4 and 5 GHz), and Matter
- Color Black
- Display Touch Screen
- Programmability Time-Based or Smart Away; Residential or Commercial
- Terminal Designations (On EIM) R, Rc, Rh, Y1, Y2, G, O/B, W1, W2-Aux 1, W3-Aux 2, L, U1, U1, U2, U2, U3, U3, S1, S1, S2, S2, S3, S3, S4, S4
- Display Size 5 sq. in
- Changeover Auto or Manual
- Setting Temperature Range (F) Heat: 40 °F to 90 °F| Cool: 50 °F to 99 °F (with optional limits)
- Setting Temperature Range (C) Heat: 4.5 °C to 32 °C| Cool: 10 °C to 37 °C (with optional limits)
- Humidification Setting Range 0% to 90% RH
- Dehumidification Setting Range10% to 100% RH