Part #ICM870-16A
Soft Start Kit 16A 120/240 VAC 2-3T

Login for Price
- Brand: ICM Controls
- Reduces in-rush current/draw necessary at startup by up to 70%
- Prolong the life of the A/C by reducing excessive torque, wear and tear
- Built-in dynamic start delay
- Reduce loud noises, light flickering, and breaker trips
- Built-in self-learning algorithm
- Over-current protection
- Over/under voltage monitoring
- Built-in start capacitor
- LED fault indicators
- Ultrasonic sealed tamper-proof enclosure
- Installation hardware is included
Note:
The ICM870 Series Soft Starts are NOT recommended to be used with air conditioners or heat pumps which have control boards that sense compressor current and perform a lock out for fault conditions.
Any Air Conditioner or Heat Pump which has a Comfort Alert control board or an Emerson Core Sense Module installed are not directly compatible for use with the ICM870 Series Soft Start.
The Emerson CoreSense module can be bypassed when using the ICM870 Series Soft Starts. Unfortunately, the circuit board and kit style Comfort Alert cannot be bypassed and therefore, ICM870 cannot be used.
Input
- (L1, L2) – 100-240 VAC 50/60Hz
- Over voltage limits: 115 VAC nominal = 140 VAC, 240 VAC nominal = 264 VAC
- Under voltage limits: 115 VAC nominal = 95 VAC, 240 VAC nominal =195 VAC
Output
- Compressor
- Solid state/relay
Current
- Max. nominal = 9 FLA for ICM870-9A, 16 FLA for ICM870-16A
- Over current limits
- ICM870-9A = 11.25A
- ICM870-16A = 20A
Environment
- Ambient temperature:
- 40°C @ 16 FLA, 8 h duty 50°C @ 16 FLA
- Temporary duty F = 30% (3 mins ON and 7 mins OFF)
- S = 6 (6 cycles per hour)
- Storage temperature: -40°F to 149°F (-40°C to 65°C)
- Humidity: 0-95% non-condensing
Mechanical
- Enclosure: IP65
- Screw Hole Center Points: 7.36” x 2.97”
Weight/Dimensions
- Length: 7.94”
- Width: 4.20”
- Height: 2.10”
