Provide electronic control of direct spark ignition systems used on gas fire furnaces, boilers, and other heating appliance.
Control ignition sequence and gas control operation|Generate high voltage potential for main burner ignition|Lockout after one trial for ignition if main burner fails to ignite|Reset from thermostat after lockout|2 sec at 2.5 mA flame failure response time|60 Hz frequency|-40 to 175 deg F ambient temperature|Single trial for main burner ignition sequence|VR8205, VR8305 gas control|Two-rod flame sense|External (120 VAC powered) high voltage spark generator|1 ignition trials to lockout|0.8 sec max flame failure re-ignition time|Use modules (except S87C) with any combination gas control designed for direct spark applications and rated 2.0A or less
Honeywell Spark Ignition Control, Direct, 24 VAC, 2 A, Liquid Propane, Natural Gas Gas, 4 s Lockout, 5-1/4 in Height, 4-1/16 in Width, 1-15/16 in Depth, Domestic/Import: Import